Two-year clinical performance of a packable posterior composite with and without a flowable composite liner
2003
The aim of the study was to evaluate the clinical performance of a packable fine hybrid dental composite (Prodigy Condensable) and the influence of the additional application of a flowable resin composite (Revolution, SDS Kerr) layer on marginal integrity after 2 years in stress-bearing posterior cavities according to the Ryge criteria. In 50 patients (40.5+/-17.5 years of age), 116 class II fillings (metal matrix system, glass ionomer-cement-base in 36%, rubberdam isolation in 70%) were placed, with at least two restorations per patient. The adhesive Optibond Solo Plus was used for all the restorations. In one of the two fillings in each patient, an additional layer of the flowable composi…
Oval fiber posts do not improve adaptation to oval-shaped canal walls.
2011
Abstract Introduction Oval fiber posts attempt to provide better adaptation to root canals. The hypothesis of this study was that there are no differences in adaptation of oval and circular fiber posts to canal walls. Methods Posts were inserted in 20 canals; 10 were oval, and 10 were circular. The posts were cemented with composite cement. Coronal, middle, and apical sections were observed through a microscope. The space occupied by the post and the maximum distance between it and the canal wall were calculated. The 2 groups were compared with analysis of variance. In all the analyses the level of significance was set at P Results The proportion of space occupied by the post showed no sign…
Sealing capacity of a photochromatic flowable composite as protective base in nonvital dental bleaching.
2006
Aim To evaluate microleakage of a flowable composite used as a protective isolating base, applied with different adhesive systems. Methodology Seventy root-filled teeth were divided into seven groups. A flowable composite base (Tetric Flow Chroma) was used with three adhesive techniques (Syntac, Excite, Excite DCS; in the three cases with and without acid etching) and in a control group without dentine conditioning or adhesive placement. A 30% hydrogen peroxide solution was applied for 24 h in the pulp chambers, followed by the placement of a dye (silver nitrate) for 4 h. Each tooth was sectioned longitudinally, and examined under 4× magnification to assess the tooth/restoration dye leaka…
Marginal integrity of class V restorations: SEM versus dye penetration.
2006
To perform an in vitro investigation on the marginal integrity of different adhesives (Optibond FL, Scotchbond 1XT, Clearfil SE Bond, Adper Prompt L-Pop, S(3) Bond, iBond exp., Adper Prompt L-Pop) in combination with Tetric Ceram as well as an experimental silorane-restorative (Hermes, Hermes Bond; 3M ESPE) using SEM and dye penetration (2% methylene blue) in a comparative manner.Standardized class V-cavities (3 mm x 1.5 mm) were prepared in 70 extracted human teeth (n=10). The adhesives were applied according to manufacturers' instructions. The cavities were restored with three increments. After finishing and polishing (Sof-Lex discs) and thermocycling (5000x, 5/55 degrees C), replicas wer…
Marginal integrity of different resin-based composites for posterior teeth: an in vitro dye-penetration study on eight resin-composite and compomer-/…
2002
Abstract Objective: To determine improvements in marginal adaptation of resin-based composite restorative systems by means of flow-composites (Solitaire 2/Gluma Solid Bond, Solitaire 2/Flow Line/Gluma Solid Bond, Point 4/Optibond Solo Plus, Point 4/Revolution/Optibond Solo Plus) and to determine the equality of simplified bonding systems (Solitaire 2/Gluma Comfort Bond, Tetric Ceram/Tetric Flow/Excite, Dyract AP/Prime & Bond NT/NRC, Pertac II/Prompt-L-Pop) in marginal gap formation. Methods: The marginal dye penetration (2% methylene-blue) was investigated separately for the approximal boxes of Class II mod-cavities with one cervical margin of the approximal box within enamel, the other wit…
The effect of composite resin preheating on marginal adaptation of class II restorations
2020
Background One of the problems with a high filler content composite resins is gap formation at restorative material-tooth interface. The present study investigated the effect of preheating composite resins on the formation of marginal gap in Cl II restorations. Material and Methods In this in vitro study Sixty Cl II cavities were prepared on the mesial and distal surfaces of 30 extracted premolar teeth. The gingival floor of cavities was placed 1 m below the CEJ. The samples were randomly allocated to 4 groups for restoration placement: group 1, Filtek P60 composite resin at room temperature; group 2, Filtek P60 composite resin at 68°C; group 3, X-tra fil composite resin at room temperature…
The Effect of Age, Gender, and Insertion Site on Marginal Bone Loss around Endosseous Implants: Results from a 3-Year Trial with Premium Implant Syst…
2014
Objectives.The goal of this study was to evaluate bone changes around endosseous implants in partially edentulous patients.Materials and Methods.A total of 632 two-stage implants were placed in 252 patients. The implants had straight emergence profile, ZirTi surface, 3.3 to 5 mm diameter, and 8.5 to 13 mm length. Bone levels were assessed on orthopantomography immediately after surgery and after 36 months and marginal bone loss (MBL) was calculated from their difference.Results.Cumulative survival rate was 98.73%. Overall MBL was 0.8 mm ± 0.03 (mean ± SEM). Higher MBL was observed around implants in the maxilla than in the mandible (P<0.007). A relation between implant diameter and MBL (…
Zirconia Removable Telescopic Dentures Retained on Teeth or Implants for Maxilla Rehabilitation. Three-Year Observation of Three Cases
2010
Abstract This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurre…
Reduction of Polymerization Shrinkage Stress and Marginal Microleakage Using Soft-Start Polymerization
2003
Purpose: This study evaluated the influence of a soft-start light-curing exposure on polymerization shrinkage stress and marginal integrity of adhesive restorations. Materials and Methods: Six resin-based composites (Pertac II, Tetric Ceram, Definite, Surefil, Solitaire, and Visio-Molar) were adhesively bonded to a cylindrical cavity (n = 9 per material/light) in a photoelastic material. Visible light-curing was applied using either the standard polymerization mode (800 mW/cm2 exposure duration 40 s) of the curing light (Elipar TriLight, 3M ESPE) or the exponential mode from the same device (ramp-curing: 150 mW/cm2 to 800 mW/cm2 within the first 15 s of a total curing time of 40 s). Polymer…
Marginal adaptation of three-unit interim restorations fabricated by the CAD-CA systems and the direct method before and after thermocycling
2020
Background Limited information is available regarding the marginal adaptation of three-unit interim restorations fabricated by different techniques from different materials. Also, the efficacy of computer-aided design/computer-aided manufacturing (CAD-CAM) systems for their fabrication is still questionable. This study aimed to assess the marginal adaptation of three-unit interim restorations fabricated by the CAD-CAM systems and the direct method from different materials before and after thermocycling. Material and Methods A sound mandibular second premolar and a second molar were prepared for a three-unit all-ceramic restoration. Metal dies were fabricated to simulate a case of mandibular…